Is Basketball A Talent Or Skill, Articles Y

requirements of the area in which the instrument is being installed. Notes: 1. Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; Logic inputs are NOT isolated by the measuring input. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. Cold junction accuracy: 0.04C/C after a warm-up of 20 minutes. Moreover, provide indication that the. View online (36 pages) or download PDF (3 MB) YOKOGAWA TC10 User manual TC10 PDF manual download and more YOKOGAWA online manuals The following, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. period. Note: For TC wiring use proper compensating cable preferable shielded. What settings should I use to output PV transmission from ananalog output terminal on TC10? On the TC10, what does it mean if AL and 1 are lit? Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. of use, service life and misuse are not covered by this warranty. The shallow depth of the controller helps to save instrument panel space. displayed value becomes 999.9C or 999.9F. The short depth of the controller helps save instrument panel space. Related Manuals for YOKOGAWA TC10-L . Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. The conguration procedure allows to take advantage of all instrument features. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. use only, in an electrical panel which encloses the rear housing. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. For supply connections use No. user must refer to the Engineering manual for special instructions. The shallow depth of the controller helps to save instrument panel space. On the TC10, I want the difference lower limit alarm to be ON 5C below the setpoint value. TC10s compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. Before connecting the output actuators, we recommend to congure the parameters to, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. The ambient temperature is in accordance with the operative, 6. Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length). The default data are those typical values loaded in the instrument prior to ship it from factory. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. Pay attention to the line resistance; a high line resistance may cause measurement errors. - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. The short depth of the controller helps save instrument panel space. that no power is being supplied to a cable to be connected. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Easy User Control for high limit or low limit, Timer (Counts the total time the setpoint is exceeded), Register to retain the maximum temperature reached, Serial communication: RS-485 Modbus (optional), IP65 front panel (when the optional panel gasket is mounted)(optional), Universal Input: TC, mV, V, mA, Pt100, Pt1000, Power consumption: 6.0 VA max. Wattmeter power consumption is the estimated hourly, energy consumption (using Load Voltage and Load Current, parameter values), computed on the previous 15 minutes. Select a mounting location having the following characteristics: 2. 2.56 in min. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. Looking for more information on our people, technology and solutions? Click here to select options, We're open Mo-Th 8am to 5:30pm. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. To avoid electrical shocks, connect power line at last. TC10. The relative humidity is in accordance with the instrument. [34] r.md equal to 1(Limit output is de-energized at power on in any cases. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). condensation); 5. The ambient temperature is in accordance with the operative, 6. IM 05C01E81-11EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10-L is a panel mounting, Class II instrument. Controller YOKOGAWA . and workmanship for 18 months from the date of manufacturing. The short depth of the controller helps save instrument panel space. Available: When a linear input is selected by [1] SenS. The short depth of the controller helps save instrument panel space. It has been designed, with compliance to the European Directives. exposed terminals and wiring on the back. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. Yes, by changing the DP setting from 0 to 1. There is minimum vibrations and no impact; There are no water or other uids (i.e. countries or regions where wiring will be installed. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. External resistance: 100W max., maximum error 25 V. Cold junction: automatic compensation between 0 to 55C. There is no parameter for specifying the output direction. parameter and than you can use the instrument. The TC10 supports easy configuration with codes for quick start-up. A ladder sequence function is included as standard. The 3-year warranty extends 36 months after shipment from our factory. What is the I/O response time of the TC10? Controller YOKOGAWA TC 10-L Engineering Manual 20 pages. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. Products and components that are subject to wear due to conditions. The TC10 is a compact single loop temperature controller with an easy-to-read 3-color LED display. The short depth of the controller helps save instrument panel space. View available part numbers. future reference. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). 2. Approximately 2 seconds or less. What is the measured current of the TC10's RTD input? In the following pages we will describe all the parameters of the instrument. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. The TC10 communication setting criteria are as follows. 6. codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. Yokogawa Electric Corporation for this Product in the EEA. use only, in an electrical panel which encloses the rear housing. Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; To avoid electrical shocks, connect power line at last. Wattmeter power consumption is the estimated hourly, energy consumption (using Load Voltage and Load Current, parameter values), computed on the previous 15 minutes. Internal auxiliary PWS: 12 VDC (10%), 20 mA max.. 0/4 to 20 mA input wiring for passive transmitter using an external pws, 0/4 to 20 mA input wiring for active transmitter. Type: Instructions manual . The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to . Do I need a minus sign ( - ) on the alarm setting value? Does the TC10 come with a terminal cover? connected between sensor and input terminals may cause errors in measurement due to excessive and/or not balanced line resistance or possible leakage currents. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. condensation); 5. 3. terminal 1 and 2 to transmitter signal output. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features 2.Using and buttons set the programmed password. (100 to 240 VAC), Insulation voltage: 3000 V AC for 1 minute between primary and secondary terminals, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Serial Communication (optional): RS-485 MODBUS. Set detailed parameter out group o1.F (output 1 function) = r.inP. SKU:WE4537266 WARNING! all phases of operation, service and repair of this instrument. and workmanship for 18 months from the date of manufacturing. Pages: 30 . Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. When installing the TC10, what is the depth in millimeters from the surface of the panel? The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. and General Specification: GS 05C01E81-11EN. High Quality SDA25x30 Pneumatic SDA25-30mm Double Acting Compact AIR Cylinder. countries or regions where wiring will be installed. Current availability for non-stock parts is "Usually ships in 7-10 business days". The. "), 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns. The short depth of the controller helps save instrument panel space. At this point the instrument restarts as for a new power ON. These meters commonly measure voltage, resistance, continuity, capacitance, and more. It has been de- signed with compliance to the European Directives. Yokogawa TC10 Manual Download for 1 TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. The UT75A also support open networks such as Ethernet communication. Input circuit: Current injection (135 A). I selected SP value transmission on TC10, but no SP value is displayed. 3.When a shielded cable is used, it should be connected at one point only. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the equip-, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. It has been de-, signed with compliance to the European Directives. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. 600W. This is a list of recorder and controller products that support the New Legislative Framework (NLF.). values and the controller output instantaneous value. Is there a controller to which I can connect a 2-wire Pt1000 sensor? Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. A ladder sequence function is included as standard. The Declaration of Conformity and the manual of the controller can. When the upper display is showing a group and the lower display is blank, this key allows to enter in the selected group. The 3-year warranty extends 36 months after shipment from our factory. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. The upper display will show PASS while the lower display shows 0; 2.Using and buttons set the value -481; 4.The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. 5.3 HOW TO ENTER THE CONFIGURATION MODES. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. View and Download Yokogawa TC10-L instruction manual online. YOKOGAWA TC10-L: Quick Manual| Brand: Want to have your manuals available on hand: always and everywhere? period. 1, This instrument is intended for permanent installation, for, indoor use only, in an electrical panel which encloses the. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. 1. What is the /GK suffix code for the TC10? At the rst start up the instrument will use a default parameter set (factory parameter set); this set is a generic one (e.g. Available: When a linear input is selected by [1] SenS. Download digitalview ALR-1400 Instructions manual . If this instrument is used in a manner not specified in this manual. The Yokogawa TC10 is a compact, all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. Note: For TC wiring use proper compensating cable preferable shielded. a TC J input is programmed). Select a mounting location having the following characteristics: 2. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: Linear 0 to 20 mA (this selection forces Out 4 = TX), Linear 4 to 20 mA (this selection forces Out 4 = TX), Note: As default, when the alarms are active, only AL1 threshold, is available at "Operator Command" level to perform non, critical tasks.